Mecc Alte PTO Generators
120/240V, Single Phase, kW @ 1.0pf, 4 leads
MODEL | TYPE | CONT KW | STBY KW | RPM |
---|---|---|---|---|
3P2S20W1302 | Capacitor | 9.5 | 10.2 | 3600 |
3P2S20FS1602 | Capacitor | 11 | 12 | 3600 |
M5S20F2302 | Capacitor | 13.5 | 15 | 3600 |
M5ECP32LN2 | AVR | 15 | 16.5 | 3600 |
M5CO28S2 | Capacitor | 25 | 27.5 | 3600 |
M7ECP28VL4 | AVR | 25 | 25.5 | 1800 |
M7ECP323S4 | AVR | 40 | 41 | 1800 |
M7ECP321L4 | AVR | 46 | 47 | 1800 |
M9ECP323L4 | AVR | 55 | 57 | 1800 |
M9ECP341S4 | AVR | 78 | 80 | 1800 |
M9ECP342S4 | AVR | 90 | 83 | 1800 |
M9ECP341L | AVR | 98 | 101 | 1800 |
M9ECP342L | AVR | 100 | 103 | 1800 |
Download Mecc Alte PTO Generator Brochure
PTO Generator Features
Gear Box – constructed of cast iron. Gears and shafts are nickel chrome alloy steel.
Gears are helical cut. Gear box is equipped with oil level indicator.
Control Box – (2) M7 and (1) M9 unit available with optional tall box.
Accessories – PTO Drive Shafts.
Voltage Regulation – AVR is powered by an auxiliary winding which guarantees constant
supply under all possible operating conditions. The voltage accuracy is ± 1% in static
conditions with any power factor, and speed variation between -10% and +30%.
Overload – Permissible overloads 300% for 10 seconds or 50% for 2 minutes; 10% for
one hour of every six. Applies to AVR regulated machines only.
Insulation & Impregnation – Insulation is Class H standard. Rotating parts are impregnated
with epoxy resin; high voltage parts are vacuum impregnated. Special treatments available
upon request- Please consult Factory.
*Specifications are subject to change without notice.